ELSR-SHH

ELSR-SHH

Self-regulating 2-conductor with screen

Usage

  • Frost protection and heating products
  • Power range 15-75 W/m
  • Wide range of uses
  • Power on: 250 °C
    250 °C
  • Power off: 250 °C
    250 °C
  • EX
    EX
  • Can be cut and crossed for perfect adaptation
  • High chemical resistance
  • Extremely high temperature resistance
The versatile self-regulating heating cable, ELSR-SHH, for high temperatures up to 250°C, can be used in a large number of industrial applications. It is also suitable and approved for use in hazardous areas. The heating cable is also resistant to reactive chemicals, oil and fuel. Thanks to the high chemical resistance, the cable also has a long service life.

ELSR-SHH

Specifications

Specification Data
Connection voltage 230 V
Number of conductors 2 pcs
Bending radius, min. 35 mm
Exposure temperature (power off), max. 250 ºC
Exposure temperature (power on), max. Up to 250 ºC
-BOT Protective conductor: Braided, Outer casing: Fluoropolymer
Installation temperature, min. -40 ºC
Insulation material outer PFA
Cable type Self-regulating 2-conductor with screen
Classification (Ex) II 2G Ex eb IIC GbII 2D Ex tb IIIC Db
Conductor area 1,27 mm²

Warranty

Below is a list of our general delivery terms.

Our warranty terms