ELP/Si
Parallel-resistive 2-conductor with screen
Usage
- Power range 10-40 W/m
- Frost protection and heating products
- Constant effect, halogen-free
-
130 °C
-
180 °C
-
Can be cut during installation for good fit
-
Soft and pliable
The installation of this heating cable is very cost effective because it is only connected at one end. The heating cable consists of a series of heating zones (length = contact distance) and the cable can be cut to the desired length in sections of the contact distance. During cutting, the heating circuit is broken up to the next contact point and this inactive part can be used as a cold conductor. During the design, a contact distance per planned heating circuit must be added.
Specifications
| Specification | Data |
|---|---|
| Connection voltage | 230 V |
| Number of conductors | 2 pcs |
| Bending radius, min. | 30 mm |
| Exposure temperature (power off), max. | 180 ºC |
| Exposure temperature (power on), max. | Up to 130 ºC |
| -BO | Protective conductor: Braided, Outer casing: TPE |
| Contains SVHC substances according to REACH | No |
| Installation temperature, min. | -60 ºC |
| Insulation material intermediate | Silicone |
| Insulation material inner | Silicone |
| Insulation material outer | Silicone |
| Cable type | Parallel-resistive 2-conductor with screen |
| Contact distance | 1 m |
| Conductor area | 1,50 mm² |