Thermoflex matta

Thermoflex

Series-resistive 2-conductor with screen on self-adhesive mat

Usage

  • Underfloor heating for tiled, natural stone and linoleum floors
  • Underfloor heating for both wet rooms and dry areas
  • Laid in levelling compound
  • Nät
    Mesh
  • Flera effekter
    Several effects
  • Efficient placement with self-adhesive mat
  • Thin cable design that provides low installation height
  • Heating cable with halogen-free outer casing
The underfloor heating mat can be used for open, regular areas of floor tile or natural stone. The mat is easily installed in one step and can be cut and angled. The heating cable is mounted on a self-adhesive, alkali-resistant fibreglass mesh with fixed c/c spacing.

Thermoflex

Specifications

Specification Data
Connection voltage 230 V
Length Connection cable 2,5 m
Number of conductors 2 pcs
Diameter 4 mm
Output 45 W/m², 60 W/m², 120 W/m²
Installation temperature, min. 18 ºC
Insulation material intermediate XLPE
Insulation material inner ETFE
Insulation material outer PE/EVA
Cable type Series-resistive 1-conductor with screen
Enclosure class IP67
Mat Alkali-resistant fibreglass mesh
Protective conductor Aluminium foil
UV resistance No

Warranty

25 års garanti

 

 

 

 

 

 

 

 

12 year product guarantee in case of material defects. The thermostat in the kit has a 5-year product guarantee. The guarantee period for the underfloor heating is extended to 25 years if the installation is carried out by an authorised electrician and documented in Ebeco's Garantera service.

Our warranty terms

Installation

Self-adhesive heating cable mat, alkali resistant fibreglass mesh with fixed c/c distance. Easy, one-step installation and can be cut and angled.

Flooring materials

Thermoflex can be installed under most commonly used flooring materials such as tiled and natural stone floors, wooden and laminate flooring and linoleum.

Check whether the material is suitable for use in combination with underfloor heating with the floor supplier.

Subflooring when screeding

Thermoflex is laid on floor constructions of concrete, plaster or chipboard and must then be screeded with a suitable levelling compound.

On uninsulated concrete floors against the ground, additional insulation is always recommended. It is also recommended that the heating is not switched off completely during the summer to counteract rising moisture.

See manual for further instructions.

Installed output

The room's power output needs are governed by how well insulated it is, its air turnover and the outdoor temperature, but in addition to these parameters, the criteria below must also be taken into account.

Maximum installed power output for different surfaces:

  • On concrete subflooring: 160 W/m²
  • On flammable subflooring: 120 W/m²

Maximum installed power output for different flooring materials:

  • Tile & natural stone floor: 160 W/m²
  • Wood & laminate flooring and linoleum: 75 W/m²

See manual for further instructions.

Examples of constructions

In screed:

Thermoflex lager
  1. Existing floors (chipboard, plasterboard or concrete) with Thermo Board insulation board, if any
  2. Primer
  3. Thermoflex
  4. Screed/Fix
  5. Tiles