FAQ
Here is a list of the most common questions we get. Please use your browser's search function to browse the page, press Ctrl + F.
-
Can I have underfloor heating under wall to wall carpet?
Yes, you can put a carpet on the floor if you have installed underfloor heating. There is no danger... Read more -
What's your warranty when it comes to underfloor heating?
Different products have different warranties. For example, we have a 10 year... Read more -
How big are the electromagnetic fields?
Electromagnetic fields in underfloor heating is a heavily debated topic. To minimize the... Read more -
How long is the F-10 frost protection cable?
Maximum length of F-10 frost protection cable is:External fitting at 100 meters Interior... Read more -
How much foil can you install together with one thermostat?
A EB-Therm thermostat can handle 30-35m ² of foil. Larger areas should be linked to a thermostat... Read more -
Can Cable Kit be casted in?
Sure, you can cast in Cable Kit. We would however recommend the product most suited for ... Read more -
Is it possible to have a Foil Kit for vinyl floors installed in wet areas?
Unfortunately not. According to the Electrical Safety Authority rules, a 230-volt foil is not... Read more -
What is the difference between Cable Kit 50, 200 & 300?
One difference between the kits is the thermostat. There is a number of variations which... Read more -
Can I add Ebisol and foil directly onto old vinyl?
No! You must always remove the old vinyl. Plasticizers in the vinyl can dissolve the... Read more -
Where are you supposed to place the sensor cables?
The sensor cable should be located on the floor below the thermostat. It lies midway... Read more -
On which surfaces can Cable Kit be installed?
Cable Kit can be installed directly onto chip/plasterboard or concrete floors. You can... Read more -
What's the CC distance?
Cc stands for centre centre and refers to the cable centre.By dividing the free area by the cable... Read more -
How can the Cable Board can be breathable?
The construction breathes because there is a hole in the board and their is a 1 mm spacing in... Read more -
Does underfloor heating result in reverse moisture migration?
There is a risk of moisture migration from damp concrete slabs if the insulation is poor... Read more -
How much does it cost to buy underfloor heating?
The cost of underfloor heating depends entirely on what particular product best suits... Read more -
Do you need a particular filler when installing Ebeco Underfloor Heating?
No, there is no particular need for a special filler. However, we recommend a fiber-reinforced... Read more -
Where can I buy Ebeco's products?
Our products are available from our distributors. Read more -
Why does the LED Light on my Thermostat Flash?
EB-Therm 350 When an error occurs, the EB-Therm turns off the heat. The LED... Read more -
How come the buttons on my thermostat does not work?
The keypad may be locked. If this is the case you will see a small key... Read more -
How much filler is required?
A good rule of thumb is to count 1.7 kg / m² and 1 mm layer of filler. For example if... Read more -
What do you need to know when it comes to flooring regulations in wet areas?
For flooring in wet areas a sealing layer is required. This applies even if you are not... Read more -
How do I avoid problems with snow and ice around skylights?
In the wintertime skylights are often covered with snow. When temperatures rise, the snow melts due... Read more